<?xml version='1.0' encoding='UTF-8'?>
<!-- Built for the portal's tests (#231), not a real building. PNNL publishes no BuildingSync example, so this file was grown field by field until PNNL's buildingsync_schematrons/multifamily.sch (commit cf9b2114a0) reports no failed rule. #284 reshaped it to also pass the BuildingSync v2.6.0 schema (BuildingSync.xsd), which PNNL checks before its rules. Every value is a placeholder. --><auc:BuildingSync xmlns:auc="http://buildingsync.net/schemas/bedes-auc/2019" version="2.6.0">
  <auc:Facilities>
    <auc:Facility ID="Facility-1">
      <auc:Sites>
        <auc:Site ID="Site-1">
          <auc:Buildings>
            <auc:Building ID="Building-1">
              <auc:PremisesName>TEST Practice Building (8 units)</auc:PremisesName>
              <auc:PremisesIdentifiers>
                <auc:PremisesIdentifier>
                  <auc:IdentifierLabel>Custom</auc:IdentifierLabel>
                  <auc:IdentifierCustomName>Audit Template Building ID</auc:IdentifierCustomName>
                  <auc:IdentifierValue>1</auc:IdentifierValue>
                </auc:PremisesIdentifier>
              </auc:PremisesIdentifiers>
              <auc:Address>
                <auc:StreetAddressDetail>
                  <auc:Simplified>
                    <auc:StreetAddress>148 TEST Practice Court</auc:StreetAddress>
                  </auc:Simplified>
                </auc:StreetAddressDetail>
                <auc:City>Madison</auc:City>
                <auc:State>WI</auc:State>
                <auc:PostalCode>53703</auc:PostalCode>
              </auc:Address>
              <auc:SpatialUnits>
                <auc:SpatialUnit>
                  <auc:SpatialUnitType>Apartment units</auc:SpatialUnitType>
                  <auc:NumberOfUnits>8</auc:NumberOfUnits>
                </auc:SpatialUnit>
              </auc:SpatialUnits>
              <auc:MultiTenant>false</auc:MultiTenant>
              <auc:ConditionedFloorsAboveGrade>1</auc:ConditionedFloorsAboveGrade>
              <auc:ConditionedFloorsBelowGrade>1</auc:ConditionedFloorsBelowGrade>
              <auc:BuildingAutomationSystem>false</auc:BuildingAutomationSystem>
              <auc:HistoricalLandmark>false</auc:HistoricalLandmark>
              <auc:FloorAreas>
                <auc:FloorArea>
                  <auc:FloorAreaType>Cooled only</auc:FloorAreaType>
                  <auc:FloorAreaValue>7200</auc:FloorAreaValue>
                </auc:FloorArea>
                <auc:FloorArea>
                  <auc:FloorAreaType>Gross</auc:FloorAreaType>
                  <auc:FloorAreaValue>7200</auc:FloorAreaValue>
                </auc:FloorArea>
                <auc:FloorArea>
                  <auc:FloorAreaType>Heated and Cooled</auc:FloorAreaType>
                  <auc:FloorAreaValue>7200</auc:FloorAreaValue>
                </auc:FloorArea>
                <auc:FloorArea>
                  <auc:FloorAreaType>Heated only</auc:FloorAreaType>
                  <auc:FloorAreaValue>7200</auc:FloorAreaValue>
                </auc:FloorArea>
              </auc:FloorAreas>
              <auc:TotalExteriorAboveGradeWallArea>1</auc:TotalExteriorAboveGradeWallArea>
              <auc:TotalExteriorBelowGradeWallArea>1</auc:TotalExteriorBelowGradeWallArea>
              <auc:TotalCommonConditionedAboveGradeWallArea>1</auc:TotalCommonConditionedAboveGradeWallArea>
              <auc:OverallWindowToWallRatio>1</auc:OverallWindowToWallRatio>
              <auc:PercentOccupiedByOwner>1</auc:PercentOccupiedByOwner>
              <auc:PercentLeasedByOwner>1</auc:PercentLeasedByOwner>
              <auc:Sections>
                <auc:Section ID="Section-1">
                  <auc:SectionType>Whole building</auc:SectionType>
                  <auc:FootprintShape>Rectangular</auc:FootprintShape>
                  <auc:Sides>
                    <auc:Side>
                      <auc:WallID IDref="Wall-1"/>
                      <auc:WindowID IDref="Window-1"/>
                    </auc:Side>
                  </auc:Sides>
                  <auc:Roofs>
                    <auc:Roof>
                      <auc:RoofID IDref="Roof-1">
                        <auc:RoofCondition>Good</auc:RoofCondition>
                      </auc:RoofID>
                    </auc:Roof>
                  </auc:Roofs>
                  <auc:Foundations>
                    <auc:Foundation>
                      <auc:FoundationID IDref="Foundation-1"/>
                    </auc:Foundation>
                  </auc:Foundations>
                  <auc:UserDefinedFields>
                    <auc:UserDefinedField>
                      <auc:FieldName>50121 HOMES Whole Building Reported Energy Savings Percentage</auc:FieldName>
                      <auc:FieldValue>36</auc:FieldValue>
                    </auc:UserDefinedField>
                  </auc:UserDefinedFields>
                </auc:Section>
                <auc:Section ID="Section-2">
                  <auc:SectionType>Space function</auc:SectionType>
                  <auc:OccupancyClassification>Multifamily</auc:OccupancyClassification>
                  <auc:OriginalOccupancyClassification>Multifamily</auc:OriginalOccupancyClassification>
                  <auc:OccupancyLevels>
                    <auc:OccupancyLevel>
                      <auc:OccupantQuantityType>Peak total occupants</auc:OccupantQuantityType>
                      <auc:OccupantQuantity>1</auc:OccupantQuantity>
                    </auc:OccupancyLevel>
                  </auc:OccupancyLevels>
                  <auc:TypicalOccupantUsages>
                    <auc:TypicalOccupantUsage>
                      <auc:TypicalOccupantUsageValue>1</auc:TypicalOccupantUsageValue>
                      <auc:TypicalOccupantUsageUnits>Hours per week</auc:TypicalOccupantUsageUnits>
                    </auc:TypicalOccupantUsage>
                    <auc:TypicalOccupantUsage>
                      <auc:TypicalOccupantUsageValue>1</auc:TypicalOccupantUsageValue>
                      <auc:TypicalOccupantUsageUnits>Weeks per year</auc:TypicalOccupantUsageUnits>
                    </auc:TypicalOccupantUsage>
                  </auc:TypicalOccupantUsages>
                  <auc:FloorAreas>
                    <auc:FloorArea>
                      <auc:FloorAreaType>Conditioned</auc:FloorAreaType>
                      <auc:FloorAreaValue>1</auc:FloorAreaValue>
                    </auc:FloorArea>
                    <auc:FloorArea>
                      <auc:FloorAreaType>Gross</auc:FloorAreaType>
                      <auc:FloorAreaValue>1</auc:FloorAreaValue>
                    </auc:FloorArea>
                  </auc:FloorAreas>
                </auc:Section>
              </auc:Sections>
              <auc:UserDefinedFields>
                <auc:UserDefinedField>
                  <auc:FieldName>Retrocommissioning Date Is Not Applicable</auc:FieldName>
                  <auc:FieldValue>true</auc:FieldValue>
                </auc:UserDefinedField>
                <auc:UserDefinedField>
                  <auc:FieldName>Year Of Last Energy Audit Is Not Applicable</auc:FieldName>
                  <auc:FieldValue>true</auc:FieldValue>
                </auc:UserDefinedField>
                <auc:UserDefinedField>
                  <auc:FieldName>Year Of Last Major Remodel Is Not Applicable</auc:FieldName>
                  <auc:FieldValue>true</auc:FieldValue>
                </auc:UserDefinedField>
                <auc:UserDefinedField>
                  <auc:FieldName>Roof Area</auc:FieldName>
                  <auc:FieldValue>1</auc:FieldValue>
                </auc:UserDefinedField>
                <auc:UserDefinedField>
                  <auc:FieldName>Metering Year Start Dates</auc:FieldName>
                  <auc:FieldValue>1</auc:FieldValue>
                </auc:UserDefinedField>
              </auc:UserDefinedFields>
            </auc:Building>
          </auc:Buildings>
        </auc:Site>
      </auc:Sites>
      <auc:Systems>
        <auc:HVACSystems>
          <auc:HVACSystem ID="HVAC-1">
            <auc:HeatingAndCoolingSystems>
              <auc:HeatingSources>
                <auc:HeatingSource ID="ID-3">
                  <auc:HeatingSourceType>
                    <auc:Furnace/>
                  </auc:HeatingSourceType>
                  <auc:UserDefinedFields>
                    <auc:UserDefinedField>
                      <auc:FieldName>Source Heating Plant ID Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Annual Heating Efficiency Units Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Annual Heating Efficiency Value Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Heating Source Condition Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Location Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Output Capacity Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Primary Fuel Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Quantity Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Year Installed Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                  </auc:UserDefinedFields>
                </auc:HeatingSource>
              </auc:HeatingSources>
              <auc:CoolingSources>
                <auc:CoolingSource ID="ID-2">
                  <auc:CoolingSourceType>
                    <auc:NoCooling/>
                  </auc:CoolingSourceType>
                  <auc:UserDefinedFields>
                    <auc:UserDefinedField>
                      <auc:FieldName>Cooling Plant ID Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Annual Cooling Efficiency Units Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Annual Cooling Efficiency Value Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Capacity Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Cooling Source Condition Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Location Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Primary Fuel Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Quantity Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                    <auc:UserDefinedField>
                      <auc:FieldName>Year Installed Is Not Applicable</auc:FieldName>
                      <auc:FieldValue>true</auc:FieldValue>
                    </auc:UserDefinedField>
                  </auc:UserDefinedFields>
                </auc:CoolingSource>
              </auc:CoolingSources>
            </auc:HeatingAndCoolingSystems>
            <auc:LinkedPremises>
              <auc:Building>
                <auc:LinkedBuildingID IDref="Building-1"/>
              </auc:Building>
            </auc:LinkedPremises>
            <auc:UserDefinedFields>
              <auc:UserDefinedField>
                <auc:FieldName>Other Central Distribution Type Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Other Distribution Equipment Type Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Outdoor Air Type Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Ventilation Type Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
            </auc:UserDefinedFields>
          </auc:HVACSystem>
        </auc:HVACSystems>
        <auc:LightingSystems>
          <auc:LightingSystem ID="Lighting-1">
            <auc:LampType>
              <auc:SolidStateLighting>
                <auc:LampLabel>LED</auc:LampLabel>
              </auc:SolidStateLighting>
            </auc:LampType>
            <auc:BallastType>No Ballast</auc:BallastType>
            <auc:LinkedPremises>
              <auc:Building>
                <auc:LinkedBuildingID IDref="Building-1"/>
              </auc:Building>
            </auc:LinkedPremises>
          </auc:LightingSystem>
        </auc:LightingSystems>
        <auc:DomesticHotWaterSystems>
          <auc:DomesticHotWaterSystem ID="DHW-1">
            <auc:DomesticHotWaterType>
              <auc:StorageTank>
                <auc:TankHeatingType>
                  <auc:Direct>
                    <auc:DirectTankHeatingSource>
                      <auc:Combustion/>
                    </auc:DirectTankHeatingSource>
                  </auc:Direct>
                </auc:TankHeatingType>
              </auc:StorageTank>
            </auc:DomesticHotWaterType>
            <auc:LinkedPremises>
              <auc:Building>
                <auc:LinkedBuildingID IDref="Building-1"/>
              </auc:Building>
            </auc:LinkedPremises>
            <auc:UserDefinedFields>
              <auc:UserDefinedField>
                <auc:FieldName>Location Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Primary Fuel Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Water Heater Efficiency Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Water Heater Efficiency Type Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Year Installed Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
            </auc:UserDefinedFields>
          </auc:DomesticHotWaterSystem>
        </auc:DomesticHotWaterSystems>
        <auc:FanSystems>
          <auc:FanSystem ID="Fan-1">
            <auc:FanControlType>Constant Volume</auc:FanControlType>
            <auc:LinkedSystemIDs>
              <auc:LinkedSystemID IDref="HVAC-1"/>
            </auc:LinkedSystemIDs>
          </auc:FanSystem>
        </auc:FanSystems>
        <auc:WallSystems>
          <auc:WallSystem ID="Wall-1">
            <auc:ExteriorWallConstruction>Wood frame</auc:ExteriorWallConstruction>
            <auc:WallInsulations>
              <auc:WallInsulation>
                <auc:WallInsulationRValue>1</auc:WallInsulationRValue>
              </auc:WallInsulation>
            </auc:WallInsulations>
          </auc:WallSystem>
        </auc:WallSystems>
        <auc:RoofSystems>
          <auc:RoofSystem ID="Roof-1">
            <auc:RoofConstruction>Wood frame</auc:RoofConstruction>
            <auc:BlueRoof>false</auc:BlueRoof>
            <auc:CoolRoof>false</auc:CoolRoof>
            <auc:GreenRoof>false</auc:GreenRoof>
            <auc:RoofInsulations>
              <auc:RoofInsulation>
                <auc:RoofInsulationRValue>1</auc:RoofInsulationRValue>
              </auc:RoofInsulation>
            </auc:RoofInsulations>
          </auc:RoofSystem>
        </auc:RoofSystems>
        <auc:FenestrationSystems>
          <auc:FenestrationSystem ID="Window-1">
            <auc:FenestrationType>
              <auc:Window/>
            </auc:FenestrationType>
            <auc:FenestrationFrameMaterial>Vinyl</auc:FenestrationFrameMaterial>
            <auc:GlassType>Low e</auc:GlassType>
          </auc:FenestrationSystem>
        </auc:FenestrationSystems>
        <auc:FoundationSystems>
          <auc:FoundationSystem ID="Foundation-1">
            <auc:UserDefinedFields>
              <auc:UserDefinedField>
                <auc:FieldName>Linked Wall ID</auc:FieldName>
                <auc:FieldValue>Wall-1</auc:FieldValue>
              </auc:UserDefinedField>
              <auc:UserDefinedField>
                <auc:FieldName>Foundation Wall R Value Is Not Applicable</auc:FieldName>
                <auc:FieldValue>true</auc:FieldValue>
              </auc:UserDefinedField>
            </auc:UserDefinedFields>
          </auc:FoundationSystem>
        </auc:FoundationSystems>
      </auc:Systems>
      <auc:Measures>
        <auc:Measure ID="Measure-1">
          <auc:SystemCategoryAffected>Heating System</auc:SystemCategoryAffected>
          <auc:LinkedPremises>
            <auc:Building>
              <auc:LinkedBuildingID IDref="Building-1"/>
            </auc:Building>
          </auc:LinkedPremises>
          <auc:TechnologyCategories>
            <auc:TechnologyCategory/>
          </auc:TechnologyCategories>
          <auc:CustomMeasureName/>
          <auc:LongDescription/>
          <auc:MeasureSavingsAnalysis>
            <auc:CalculationMethod>
              <auc:Modeled>
                </auc:Modeled>
            </auc:CalculationMethod>
          </auc:MeasureSavingsAnalysis>
          <auc:UsefulLife>1</auc:UsefulLife>
          <auc:MeasureTotalFirstCost>96000</auc:MeasureTotalFirstCost>
          <auc:Recommended>false</auc:Recommended>
          <auc:UserDefinedFields>
            <auc:UserDefinedField>
              <auc:FieldName>Implementation Year</auc:FieldName>
              <auc:FieldValue>1990</auc:FieldValue>
            </auc:UserDefinedField>
          </auc:UserDefinedFields>
        </auc:Measure>
      </auc:Measures>
      <auc:Reports>
        <auc:Report ID="Report-1">
          <auc:Scenarios>
            <auc:Scenario ID="Scenario-1">
              <auc:ScenarioName>Audit Template Available Energy</auc:ScenarioName>
              <auc:ResourceUses>
                <auc:ResourceUse ID="RU-1">
                  <auc:EnergyResource>Electricity</auc:EnergyResource>
                  <auc:ResourceBoundary>Site</auc:ResourceBoundary>
                  <auc:ResourceUnits>kWh</auc:ResourceUnits>
                  <auc:EndUse>All end uses</auc:EndUse>
                </auc:ResourceUse>
              </auc:ResourceUses>
              <auc:LinkedPremises>
                <auc:Building>
                  <auc:LinkedBuildingID IDref="Building-1"/>
                </auc:Building>
              </auc:LinkedPremises>
            </auc:Scenario>
            <auc:Scenario ID="Scenario-2">
              <auc:ScenarioName>Audit Template Energy Supply Sources</auc:ScenarioName>
              <auc:ResourceUses>
                <auc:ResourceUse ID="RU-2">
                  <auc:EnergyResource>Electricity</auc:EnergyResource>
                  <auc:ResourceBoundary>Site</auc:ResourceBoundary>
                  <auc:ResourceUnits>kWh</auc:ResourceUnits>
                  <auc:UtilityIDs>
                    <auc:UtilityID IDref="Utility-1"/>
                  </auc:UtilityIDs>
                </auc:ResourceUse>
              </auc:ResourceUses>
              <auc:LinkedPremises>
                <auc:Building>
                  <auc:LinkedBuildingID IDref="Building-1"/>
                </auc:Building>
              </auc:LinkedPremises>
            </auc:Scenario>
            <auc:Scenario ID="Scenario-3">
              <auc:ScenarioName>Audit Template Energy Uses</auc:ScenarioName>
              <auc:ResourceUses>
                <auc:ResourceUse ID="RU-3">
                  <auc:EnergyResource>Electricity</auc:EnergyResource>
                  <auc:ResourceBoundary>Site</auc:ResourceBoundary>
                  <auc:ResourceUnits>kWh</auc:ResourceUnits>
                  <auc:EndUse>All end uses</auc:EndUse>
                  <auc:AnnualFuelUseNativeUnits>1</auc:AnnualFuelUseNativeUnits>
                </auc:ResourceUse>
              </auc:ResourceUses>
              <auc:LinkedPremises>
                <auc:Building>
                  <auc:LinkedBuildingID IDref="Building-1"/>
                </auc:Building>
              </auc:LinkedPremises>
            </auc:Scenario>
            <auc:Scenario ID="Scenario-4">
              <auc:ScenarioType>
                <auc:Other/>
              </auc:ScenarioType>
              <auc:ResourceUses>
                <auc:ResourceUse ID="ID-1">
                  <auc:EnergyResource>Electricity</auc:EnergyResource>
                  <auc:ResourceBoundary>Site</auc:ResourceBoundary>
                  <auc:ResourceUnits>kWh</auc:ResourceUnits>
                </auc:ResourceUse>
                <auc:ResourceUse ID="RU-4">
                  <auc:EnergyResource>Electricity</auc:EnergyResource>
                  <auc:ResourceBoundary>Site</auc:ResourceBoundary>
                  <auc:ResourceUnits>kWh</auc:ResourceUnits>
                </auc:ResourceUse>
              </auc:ResourceUses>
              <auc:TimeSeriesData>
                <auc:TimeSeries ID="TS-1">
                  <auc:StartTimestamp>2025-01-01T00:00:00</auc:StartTimestamp>
                  <auc:EndTimestamp>2025-12-31T23:59:59</auc:EndTimestamp>
                  <auc:ResourceUseID IDref="RU-4"/>
                </auc:TimeSeries>
              </auc:TimeSeriesData>
              <auc:LinkedPremises>
                <auc:Building>
                  <auc:LinkedBuildingID IDref="Building-1"/>
                </auc:Building>
              </auc:LinkedPremises>
              <auc:UserDefinedFields>
                <auc:UserDefinedField>
                  <auc:FieldName>Other Scenario Type</auc:FieldName>
                  <auc:FieldValue>Audit Template Energy Meter Readings</auc:FieldValue>
                </auc:UserDefinedField>
              </auc:UserDefinedFields>
            </auc:Scenario>
            <auc:Scenario ID="Scenario-5">
              <auc:ScenarioName/>
              <auc:ScenarioType>
                <auc:PackageOfMeasures ID="PackageOfMeasures-1">
                  <auc:AnnualSavingsCost>1</auc:AnnualSavingsCost>
                  <auc:AnnualPeakElectricityReduction>1</auc:AnnualPeakElectricityReduction>
                </auc:PackageOfMeasures>
              </auc:ScenarioType>
              <auc:LinkedPremises>
                <auc:Building>
                  <auc:LinkedBuildingID IDref="Building-1"/>
                </auc:Building>
              </auc:LinkedPremises>
              <auc:UserDefinedFields>
                <auc:UserDefinedField>
                  <auc:FieldName>Recommended Resource Savings Category</auc:FieldName>
                  <auc:FieldValue>Low Cost and No Cost Recommendations</auc:FieldValue>
                </auc:UserDefinedField>
              </auc:UserDefinedFields>
            </auc:Scenario>
          </auc:Scenarios>
          <auc:Utilities>
            <auc:Utility ID="Utility-1"/>
          </auc:Utilities>
          <auc:LinkedPremisesOrSystem>
            <auc:Building>
              <auc:LinkedBuildingID IDref="Building-1"/>
            </auc:Building>
          </auc:LinkedPremisesOrSystem>
          <auc:UserDefinedFields>
            <auc:UserDefinedField>
              <auc:FieldName>Audit Template Report Type</auc:FieldName>
              <auc:FieldValue>50121 HOMES Template</auc:FieldValue>
            </auc:UserDefinedField>
            <auc:UserDefinedField>
              <auc:FieldName>50121 Program Pathway</auc:FieldName>
              <auc:FieldValue>Modeled Energy Savings</auc:FieldValue>
            </auc:UserDefinedField>
            <auc:UserDefinedField>
              <auc:FieldName>Audit Date For Level 1: Walk-through Is Not Applicable</auc:FieldName>
              <auc:FieldValue>true</auc:FieldValue>
            </auc:UserDefinedField>
            <auc:UserDefinedField>
              <auc:FieldName>Audit Date For Level 2: Energy Survey and Analysis Is Not Applicable</auc:FieldName>
              <auc:FieldValue>true</auc:FieldValue>
            </auc:UserDefinedField>
            <auc:UserDefinedField>
              <auc:FieldName>Audit Date For Level 3: Detailed Survey and Analysis Is Not Applicable</auc:FieldName>
              <auc:FieldValue>true</auc:FieldValue>
            </auc:UserDefinedField>
            <auc:UserDefinedField>
              <auc:FieldName>Auditor Years Of Experience</auc:FieldName>
              <auc:FieldValue>1</auc:FieldValue>
            </auc:UserDefinedField>
          </auc:UserDefinedFields>
        </auc:Report>
      </auc:Reports>
      <auc:Contacts>
        <auc:Contact ID="Contact-1">
          <auc:UserDefinedFields>
            <auc:UserDefinedField>
              <auc:FieldName>Contact Role For Report-1</auc:FieldName>
              <auc:FieldValue>Energy Auditor</auc:FieldValue>
            </auc:UserDefinedField>
          </auc:UserDefinedFields>
        </auc:Contact>
        <auc:Contact ID="Contact-2">
          <auc:UserDefinedFields>
            <auc:UserDefinedField>
              <auc:FieldName>Contact Role For Report-1</auc:FieldName>
              <auc:FieldValue>Owner</auc:FieldValue>
            </auc:UserDefinedField>
          </auc:UserDefinedFields>
        </auc:Contact>
      </auc:Contacts>
    </auc:Facility>
  </auc:Facilities>
</auc:BuildingSync>